JennAir refrigeration

JennAir refrigerator repair for columns, built-ins and ice

A JennAir column in Showroom mode keeps its lights on and stops cooling, with "Showroom" lit on the display. Hold Top Zone and the JennAir logo for 3 seconds to leave it. We repair JennAir fridges, columns and ice makers.

Compact kitchen with a stainless side-by-side refrigerator beside a gas range and an over-range microwave

When a JennAir fridge only looks broken

A few JennAir refrigerator complaints come from a setting, a filter or the outlet rather than a failed part. Check these six before booking. If the trouble stays after the fix, that is the point to call us.

Lit but warm

On a column, Showroom mode runs the lights and stops cooling. Look for the word on the display.

Buzzing, frozen lettuce

An ice maker switched on with no water line can buzz and drive the fridge too cold. Turn it off.

Slow ice

For ice making, the freezer should sit between 0°F and 5°F. Warmer than that, output drops.

Weak water flow

A filter not locked in can cut the flow. So can low supply pressure: JennAir wants 30 to 120 psi, best at 40 to 80.

Drip at the filter

A loose filter can also leak at its housing. Seat it fully before calling about a leak.

Dead after a remodel

JennAir rules out wall-switched outlets and extension cords for built-ins. Check for either one.

JennAir fridge numbers

37°F
Fresh food target; 32°F to 40°F is the safe band
0°F
Freezer target
3.2 lbs
Normal daily ice from a built-in
2 min
Power cut that clears Showroom mode on a column

Sources: JennAir help site articles on control settings, ice production, built-in and column cooling, Showroom mode and ice maker troubleshooting

New built-in

Ice from a new JennAir built-in: normal or not?

StageWhat JennAir expectsWhen to call
First iceAbout 24 hours after the water is connectedNothing in the tray after a full day and night
Early batchesThrow out the first 3Not a fault; part of start-up
Full bin2 to 3 daysThe bin is still near empty after that
Daily outputAbout 3.2 lbsFar less, with the freezer at 0°F to 5°F
Power supply

What outlet does a JennAir built-in or column need?

A grounded 115 volt, 60 Hz outlet on a 15 or 20 amp fused circuit, ideally one that feeds nothing else. JennAir rules out two shortcuts. The outlet must not be controlled by a wall switch, where someone can turn the fridge off with the lights. And it must never run through an extension cord. When a built-in or column stops cooling after kitchen work, the outlet is the first thing we check.

01

Columns and settings

Some displays use Top Zone with Bottom Zone instead of the logo, held for 3 seconds. Failing that, cut power to the column for 2 minutes and it comes back out of Showroom.
37°F for fresh food and 0°F for the freezer.
Yes, both, along with built-ins and the French door and side-by-side models. Columns share the Showroom setting and the power needs on this page, so the same first checks apply to each.
JennAir tells owners to discard the first 3 batches, so plan on that before the bin starts to fill.
JennAir recommends an everydrop filter, changed every 6 months or when the light comes on. It has to lock in, or it can drip at the housing and slow the water. On a reverse osmosis system, JennAir says to remove or bypass the fridge filter, and the inlet valve needs 40 to 60 psi.
02

Water, power and visits

JennAir's guidance is that it ideally should not. A dedicated 15 or 20 amp circuit avoids the question.
Possibly, if it is a side-by-side or top-freezer sold from 2001 to 2004. A March 2009 recall covered about 1.6 million of those under Maytag-family names, Jenn-Air among them, because the relay that starts the compressor could overheat; there were 41 reports of relays igniting. Send us the model and serial and we can compare them for you.
Give it 24 hours, which is the wait JennAir sets between adjustments. Only change the control again after that if the fresh food section still sits outside 32°F to 40°F.
Yes, on built-ins, columns and freestanding models. If ice forms but never drops, try JennAir's reset first: unplug the fridge for 1 minute, then check the bin a couple of hours later.
The style (column, built-in, French door or side-by-side), the model and serial, any words or codes on the display, the temperatures you read, and how the ice maker is fed. JennAir wants 1/4 inch copper or PEX with a service loop, since pushing the fridge too far back can pinch the line. Mention a recent move or install too.

JennAir fridge warm with the lights still on?

Talk to a person
(808) 219-0537